9Bobcat T40140with PlatformOperation and Maintenance ManualControls and IndicatorsRadio control transmitterThis transmitter is comprised of a box which is fixed onto the people carrier which is the usual driving post when the machine is used as a PEMP.In this paragraph, the controls are described considering the operator to be normally positioned in the driving post, i.e.:• in the people carrier.• opposite the transmitter, i.e. by the barrier on the han-dler side.Front sideThere are two adjusting screws on this side to fasten the transmitter onto the people carrier.Figure 10Right sideFigure 11WARNINGWhen using the remote control the contact of the transmitter must always remain in position "1".WARNINGPlease make sure that all other energy consumers (steering mode, headlights, cabin ventilation, etc.) remainswitched off when using the remote control.IMPORTANTThis paragraph presents the controls, indicators and equipment which the machine is equipped with when used as a PEMP.Controls, indicators and equipment for use as a telescopic handler with PEMP are the same as for the regular tele-scopic handler without specific PEMP equipment; read the applicable paragraphs in the telescopic handler operator's instructions.93874ReferenceDescriptionFunction1Power plugThis plug (7-pin) connects thetransmitter to the platform via the cable located on the platform.• If this plug is not connected to the platform, the radio control will not function.• Do not attempt to activate the machine by any other means if this plug is not connected.93971